three-point atlantoaxial fixation with c1–c2 transarticular screws and c1 lateral mass screws
Clicks: 430
ID: 154899
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
76.6
/100
430 views
340 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #1 of 12 articles by views in journal of the marine biological association of the united kingdom
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background: Based on established posterior atlantoaxial fixation techniques, we present a novel technique that uses a polyaxial screw rod system and utilizes a combination of C1 lateral mass and C1–C2 transarticular screws. Methods: We conducted a retrospective review of six men and four women (mean age: 57, range: 20–86). Indication for atlantoaxial fixation was type II odontoid fractures or pseudarthrosis after odontoid fracture ( n = 7), rheumatoid arthritis ( n = 2) and os odontoideum ( n = 1). Results: The mean follow-up time was 48 months (range: 24–72). There were no intraoperative complications such as vertebral artery, nerve root or spinal cord injury. Post-operative imaging showed no screw malposition. During follow-up, no patient had screw loosening, screw fracture or bone absorption around the screws. Clinically, patient neck pain improved in all cases. Conclusions: C1 lateral mass and C1–C2 transarticular polyaxial screw rod fixation is a novel and potentially effective surgical technique for achieving immediate rigid immobilization of the C1–C2 motion segment. However, further biomechanical studies should be performed to prove our clinical results.
| Reference Key |
harati2019journalthree-point
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Ali Harati;Paul Oni |
| Journal | journal of the marine biological association of the united kingdom |
| Year | 2019 |
| DOI |
10.1177/2309499019854201
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.