first continuous measurements of δ18o-co2 in air with a fourier transform infrared spectrometer
Clicks: 200
ID: 154833
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
200 views
37 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #62 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The continuous in situ measurement of δ18O in atmospheric CO2
opens a new door to differentiating between CO2 source and sink
components with high temporal resolution. Continuous
13C–CO2 measurement systems have already been commercially available for some time,
but until now, only few instruments have been able to provide a continuous
measurement of the oxygen isotope ratio in CO2. Besides precise
13C/12C observations, the Fourier transform infrared (FTIR)
spectrometer is also able to measure the 18O / 16O ratio in
CO2, but the precision and accuracy of the measurements have not yet
been evaluated. Here we present a first analysis of δ18O-CO2 (and δ13C-CO2) measurements with the
FTIR analyser in Heidelberg. We used Allan deviation to determine the
repeatability of δ18O-CO2 measurements and found that it
decreases from 0.25‰ for 10 min averages to about
0.1‰ after 2 h and remains at that value up to
24 h. We evaluated the measurement precision over a 10-month period
(intermediate measurement precision) using daily working gas measurements
and found that our spectrometer measured δ18O-CO2 to
better than 0.3‰ at a temporal resolution of less than
10 min. The compatibility of our FTIR-spectrometric measurements to
isotope-ratio mass-spectrometric (IRMS) measurements was determined by
comparing FTIR measurements of cylinder gases and ambient air with IRMS
measurements of flask samples, filled with gases of the same cylinders or
collected from the same ambient air intake. Two-sample t tests revealed
that, at the 0.01 significance level, the FTIR and the IRMS measurements do
not differ significantly from each other and are thus compatible. We
describe two weekly episodes of ambient air measurements, one in winter and
one in summer, and discuss what potential insights and new challenges
combined highly resolved CO2, δ13C-CO2 and δ18O-CO2 records may provide in terms of better understanding
regional scale continental carbon exchange processes.
| Reference Key |
vardag2015atmosphericfirst
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;S. N. Vardag;S. Hammer;M. Sabasch;D. W. T. Griffith;I. Levin |
| Journal | bioorganic & medicinal chemistry |
| Year | 2015 |
| DOI |
10.5194/amt-8-579-2015
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.