reliability of hindfoot alignment using weightbearing ct semi automatic software
Clicks: 288
ID: 152988
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
288 views
24 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 6 articles by views in journal of human development and capabilities
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Category: Ankle, Hindfoot, Imaging Introduction/Purpose: Hindfoot Alignment (HA) on 2D radiographs presents anatomical and operator-related bias. In this study, weightbearing CT (WBCT) was used to measure HA using a semi-automatic software which gives HA as a value of Foot Ankle Offset (FAO) after selecting four landmarks (weight bearing points of first and fifth Metatarsals, Calcaneus and center of the ankle joint). We assessed the intra and interobserver reproducibility and the distribution of FAO values in a series of datasets from clinically normal, varus and valgus cases. We hypothesized that reproducibility would be excellent. Furthermore, FAO in normals should have a Gaussian distribution and be significantly different to the varus and valgus groups. Methods: In this level 3, retrospective comparative study, WBCT (PedCAT ®, CurveBeam LLC, Warrington, PA, USA) datasets were obtained from an existing database. The 135 feet were assessed by a senior foot and ankle surgeon as normal, varus or valgus (57, 38 and 40 respectively). Two surgeon investigators (one senior and one trainee) independently analyzed each case using a semi-automatic HA measurement tool (TALAS ™, CurveBeam LLC, Warrington, PA, USA). A third, independent investigator conducted the statistical analysis using Stata® Software. Results: The overall intraoberver and interobserver reliability were 0.99 ± 0.002 and 0.97 ± 0.02 respectively. In normal cases, mean value for FAO was 2.38% ± 2.96, whereas in varus and valgus cases mean was -11.67% ± 6.90 and 11.47% ± 5.79, respectively (p<0.001). The normal population had a Gaussian distribution with a Kolmogorov-Smirnov test > 0.8 Conclusion: This study reports excellent reliability and discriminative power of a semi-automatic 3D measurement tool for Hindfoot Alignment in WBCT.
| Reference Key |
md2017footreliability
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Francois Lintz MD;Matthew Welck MD, FRCS(Orth);Alessio Bernasconi MD;James Thornton BSc;Nicholas Cullen FRCS(Orth);Dishan Singh MB,ChB,FRCS(Orth);Andrew Goldberg MD, MBBS, FRCS(Tr&Orth) |
| Journal | journal of human development and capabilities |
| Year | 2017 |
| DOI |
10.1177/2473011417S000058
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.