two-dimensional matrix algorithm using detrended fluctuation analysis to distinguish burkitt and diffuse large b-cell lymphoma
Clicks: 234
ID: 152830
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
234 views
28 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #28 of 191 articles by views in advanced functional materials
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 191 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A detrended fluctuation analysis (DFA) method is applied to image analysis. The 2-dimensional (2D) DFA algorithms is proposed for recharacterizing images of lymph sections. Due to Burkitt lymphoma (BL) and diffuse large B-cell lymphoma (DLBCL), there is a significant different 5-year survival rates after multiagent chemotherapy. Therefore, distinguishing the difference between BL and DLBCL is very important. In this study, eighteen BL images were classified as group A, which have one to five cytogenetic changes. Ten BL images were classified as group B, which have more than five cytogenetic changes. Both groups A and B BLs are aggressive lymphomas, which grow very fast and require more intensive chemotherapy. Finally, ten DLBCL images were classified as group C. The short-term correlation exponent α1 values of DFA of groups A, B, and C were 0.370±0.033, 0.382±0.022, and 0.435±0.053, respectively. It was found that α1 value of BL image was significantly lower (P<0.05) than DLBCL. However, there is no difference between the groups A and B BLs. Hence, it can be concluded that α1 value based on DFA statistics concept can clearly distinguish BL and DLBCL image.
| Reference Key |
yeh2012computationaltwo-dimensional
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Rong-Guan Yeh;Chung-Wu Lin;Maysam F. Abbod;Jiann-Shing Shieh |
| Journal | advanced functional materials |
| Year | 2012 |
| DOI |
10.1155/2012/947191
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.