air bubble and viscoelastic agents in production of posterior capsular opacity and pigment deposition over the intraocular lens

Clicks: 213
ID: 152671
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #73 of 133 articles by views in 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 133 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: In cataract surgery, viscoelastic agents form anterior chamber, complicating to posterior capsular opacity and pigment deposition over intraocular lens after lens implantation. We compared the rate of these complications for air bubble and viscoelastic agents. Methods: Patients with senile cataract and candidate for routine cataract extraction were studied. They were randomly divided into group A (n=62) and group B (n=66). During operation and at the time of intraocular lens implantation, anterior chamber was formed by air bubble (in group A) and with viscoelastic agents (in group B). All patients were followed for 3 to 6 months. Results: The rate of posterior capsular opacity and pigment deposition over the intraocular lens were significantly higher in group B (40.9% vs. 21%) than group A (30.3% vs. 9.7%), respectively. Conclusion: Air bubble is a good substitution for viscoelastic agents in the formation of anterior chamber during cataract, either for decreasing complications or expensive materials. Keywords: Posterior capsular opacity, cataract extraction, viscoelastic agent, air bubble
Reference Key
attarzadeh2006journalair Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;H Attarzadeh
Journal 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings
Year 2006
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.