Tubes for detection of cholinesterase inhibitors-Unique effects of Neusilin on the stability of butyrylcholinesterase-impregnated carriers.
Clicks: 387
ID: 1519
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
63.3
/100
387 views
273 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #3 of 249 articles by views in Enzyme and microbial technology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 249 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Detection tubes are small devices for the colorimetric enzymatic detection of cholinesterase inhibitors such as sarin, soman, VX nerve agents and substances denoted as Novichok. These detectors contain carriers in the form of pellets with immobilized cholinesterase, substrate and detection reagent. Their advantages are portability, sensitivity and simplicity, enabling fast detection of such compounds from air and water in case of a terrorist attack or war. In general, maintaining the stability of an enzyme for a longer time is very problematic; therefore, its further enhancement is required for safety and financial reasons. In this study, the stability of our patented carriers in the form of pellets with immobilized butyrylcholinesterase containing an increasing amount of the unique sorbent Neusilin US2 was evaluated. The samples containing Neusilin maintained the stability of the immobilized enzyme for a longer time even at higher temperature and humidity than the currently commercially used carrier without Neusilin, allowing improved detection of nerve agents.
| Reference Key |
zeman2019tubes
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zeman, Jiří;Vetchý, David;Pavloková, Sylvie;Franc, Aleš;Pitschmann, Vladimír;Dominik, Martin;Urbanová, Martina;Šeděnková, Ivana; |
| Journal | Enzyme and microbial technology |
| Year | 2019 |
| DOI |
S0141-0229(19)30069-9
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.