confiabilidade da medida de espessuras musculares pela ultrassonografia reliability of muscle thickness measurements using ultrasound
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #8 of 73 articles by views in research disclosure
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
PURPOSE: To determine the reliability of muscle thickness measurements of elbow and knee flexors and extensors using ultrasound, and to quantify the typical error associated to the measurements (TEM). METHODS: The test-retest reliability was determined in 15 apparently healthy volunteers (8 women, 34 ± 11 years, 76 ± 21 kg, 170 ± 10 cm). The images of elbow flexors (EF) and extensors (EE) and knee flexors (KF) and extensors (KE) were obtained using a two dimensional mode B ultrasound instrument with a 7.5 MHz transducer. Muscle thickness between the adipose tissue and bone interfaces were measured at anatomical landmarks previously identified and recorded to assure the exact site for the retest. RESULTS: ANOVA did not identify any significant differences between the repeated measurements. Intraclass correlation coefficients (ICC) of each pair of measure were EF = 0.970, EE = 0.971, KF = 0.555 e KE = 0.929 (P < 0.05 for all). The coefficients of variation were 3.9 %, 6.1 %, 6.6 % e 4.6 %, and TEM 1.3 mm, 1.6 mm, 4.9 mm e 1.9 mm, respectively, for the EF, EE, KF and KE thickness. Analysis of the Bland-Altman plot charts indicated that the variables did not present heterocedastic errors. CONCLUSION: EF, EE and KE muscle thickness measurements using the current method were highly reliable and can be used to measure and monitor changes in diet, physical training and rehabilitation programs. Nevertheless, KF measure should not be recommended since it presented low reliability and high TEM.
| Reference Key |
gomes2010revistaconfiabilidade
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Paulo Sergio Chagas Gomes;Cláudia de Mello Meirelles;Sandra Pereira Leite;Carlos Antonio Barbosa Montenegro |
| Journal | research disclosure |
| Year | 2010 |
| DOI |
10.1590/S1517-86922010000100008
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.