experimental and numerical study on the resistance performance of an axial flow cyclone separator
Clicks: 123
ID: 150153
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
123 views
9 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #536 of 1,093 articles by views in journal of power sources
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,093 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The purpose of this paper is to study the pressure drop of an axial flow cyclone separator as a function of inlet velocities using experimental and computational fluid dynamics (CFD) methods. First, the resistance performance of the separator was acquired under ambient pressure and temperature with little change by wind tunnel experiments. Then, numerical simulations were carried out in CFD code Fluent 6.3 under standard operating conditions. A comparison between the experimental and CFD data demonstrates that the CFD method can predict the pressure drop of the axial cyclone separator excellently. Additionally, the results show that the axial flow cyclone separators have a pressure drop coefficient of approximately 7.5. To study the effect of ambient pressure and temperature on pressure drops, the same CFD method was employed to predict the resistance performance under various operating conditions. Then the numerical results were compared with the data of a normalization process method of pressure drops raised in this paper. Their comparison demonstrated that the normalization method had a high precision in predicting the influence of ambient operating parameters on pressure drops of an axial flow cyclone separator.
| Reference Key |
luan2015mathematicalexperimental
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Yigang Luan;Haiou Sun |
| Journal | journal of power sources |
| Year | 2015 |
| DOI |
10.1155/2015/384524
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.