performance of psa and of psa density in the diagnosis of prostate carcinoma

Clicks: 283
ID: 149897
2002
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #81 of 132 articles by views in forensic science international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 132 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVE: The aim of the study was to investigate the influence of the prostate volume and PSA density on the performance of total PSA to diagnosis of prostate carcinoma. METHODS: We analyzed 217 patients (PSA 0-10ng/ml) submitted to transrectal sextant prostate biopsy. Criteria for biopsy indication was PSA >2ng/ml and/or digital rectal exam suspicious of prostate cancer. RESULTS: Fifty five patients had prostate neoplasia (25.3%) and in 8/55 (25.3%) the serum PSA was under 4ng/ml. The sensitivity and specificity of the test were respectively 98.2% / 16.6% at a cut-off point of 2.5ng/ml and 85.4% / 38.8% at cut-off of 4ng/ml. The corresponding values for prostates >40ml or <40ml were: 96.2% / 8.1% and 100% / 27.2% at the cut-off point of 2.5ng/ml, and 92.5% / 20% and 78.5% / 62.3% at a cut-off level of 4ng/ml. For prostates <40ml a PSA cut-off point of 4ng/ml leads to a misdiagnosis in 21.4% of the malignant tumors. The median PSAD of benign prostates are different according to prostate volume (.40ml or <40ml). PSAD at cut-off of 0.08 increases the PSA specificity at both PSA cut-off points. CONCLUSIONS: Prostate volume affects the sensitivity and specificity of PSA and the median values of PSAD. PSAD of 0.08 increases the PSA specificity specially at a cut-off point of 2.5ng/ml in prostates smaller than 40ml.
Reference Key
martins2002actaperformance Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal forensic science international
Year 2002
DOI
10.1590/S0102-86502002000900002
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.