evaluation of visual-evoked cerebral metabolic rate of oxygen as a diagnostic marker in multiple sclerosis
Clicks: 252
ID: 149086
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
252 views
42 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #27 of 42 articles by views in bulletin of chemical reaction engineering & catalysis
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A multiple sclerosis (MS) diagnosis often relies upon clinical presentation and qualitative analysis of standard, magnetic resonance brain images. However, the accuracy of MS diagnoses can be improved by utilizing advanced brain imaging methods. We assessed the accuracy of a new neuroimaging marker, visual-evoked cerebral metabolic rate of oxygen (veCMRO2), in classifying MS patients and closely age- and sex-matched healthy control (HC) participants. MS patients and HCs underwent calibrated functional magnetic resonance imaging (cfMRI) during a visual stimulation task, diffusion tensor imaging, T1- and T2-weighted imaging, neuropsychological testing, and completed self-report questionnaires. Using resampling techniques to avoid bias and increase the generalizability of the results, we assessed the accuracy of veCMRO2 in classifying MS patients and HCs. veCMRO2 classification accuracy was also examined in the context of other evoked visuofunctional measures, white matter microstructural integrity, lesion-based measures from T2-weighted imaging, atrophy measures from T1-weighted imaging, neuropsychological tests, and self-report assays of clinical symptomology. veCMRO2 was significant and within the top 16% of measures (43 total) in classifying MS status using both within-sample (82% accuracy) and out-of-sample (77% accuracy) observations. High accuracy of veCMRO2 in classifying MS demonstrated an encouraging first step toward establishing veCMRO2 as a neurodiagnostic marker of MS.
| Reference Key |
hubbard2017brainevaluation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Nicholas A. Hubbard;Yoel Sanchez Araujo;Camila Caballero;Minhui Ouyang;Monroe P. Turner;Lyndahl Himes;Shawheen Faghihahmadabadi;Binu P. Thomas;John Hart;Hao Huang;Darin T. Okuda;Bart Rypma |
| Journal | bulletin of chemical reaction engineering & catalysis |
| Year | 2017 |
| DOI |
10.3390/brainsci7060064
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.