multiplexed lateral flow test for detection and differentiation of cronobacter sakazakii serotypes o1 and o2

Clicks: 210
ID: 148971
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #736 of 875 articles by views in journal of magnetic resonance (san diego, calif : 1997)

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 875 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The ubiquitous and opportunistic pathogen Cronobacter sakazakii is responsible for severe meningitis, sepsis, and necrotizing enterocolitis in neonates and infants associated with ingestion of contaminated powdered infant formula (PIF). The current ISO method for isolation and detection of Cronobacter spp. is laborious, time-consuming and expensive. In this study, a multiplexed lateral flow test strip was developed to rapidly detect and simultaneously serotype O1 and O2 C. sakazakii serotypes. The assay is based on two monoclonal antibodies (MAb) that specifically bind to the lipopolysaccharides (LPS) of these pathogens. The test strip provides results very quickly; C. sakazakii could be detected in pure culture within 15 min with a sensitivity of 107 CFU/ml. After non-selective enrichment for 18 h as low as one Cronobacter cell per g PIF could be detected. Moreover, the established lateral flow assay (LFA) offers excellent specificity showing no cross-reactivity with other C. sakazakii serotypes, Cronobacter species or Enterobacteriaceae tested. These characteristics, together with several advantages such as speed, simplicity in performance, low analysis cost, and no requirement of specialized skills or sophisticated equipment make the developed multiplexed LFA suitable for reliable detection and serotyping of C. sakazakii serotypes O1 and O2.
Reference Key
scharinger2017frontiersmultiplexed Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Eva J. Scharinger;Richard Dietrich;Tobias Wittwer;Erwin Märtlbauer;Kristina Schauer
Journal journal of magnetic resonance (san diego, calif : 1997)
Year 2017
DOI
10.3389/fmicb.2017.01826
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org