Abstract
Background. Allospecific anti-HLA antibodies (Abs) are associated with rejection of solid organ grafts. The 2 main kits to detect anti-HLA Ab in patient serum are commercialized by Immucor and One Lambda/ThermoFisher. We sought to compare the performance of both platforms. Methods. Background-adjusted mean fluorescence intensity (MFI) values were used from both platforms to compare sera collected from 125 pretransplant and posttransplant heart and lung transplant recipients. Results. Most HLA class I (94.5%) and HLA class II (89%) Abs with moderate to high MFI titer (≥4000) were detected by both assays. A modest correlation was observed between MFI values obtained from the 2 assays for both class I (r = 0.3, r2 = 0.09, P < 0.0001) and class II Ab (r = 0.707, r2 = 0.5, P < 0.0001). Both assays detected anti–class I and II Ab that the other did not; however, no specific HLA allele was detected preferentially by either of the 2 assays. For a limited number of discrepant sera, dilution resulted in comparable reactivity profiles between the 2 platforms. Conclusions. Immucor and One Lambda/ThermoFisher assays have a similar, albeit nonidentical, ability to detect anti-HLA Ab. Although the correlation between the assays was present, significant variances exist, some of which can be explained by a dilution-sensitive “prozone” effect.
Reference Key
msc2017transplantationcomparative Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Kevin J. Clerkin, MD, MSc;Sarah B. See, PhD;Maryjane A. Farr, MD, MSc;Susan W. Restaino, MD;Geo Serban, PhD;Farhana Latif, MD;Lingzhi Li;Paolo C. Colombo, MD;George Vlad, PhD;Bryan Ray, PhD;Elena R. Vasilescu, MD;Emmanuel Zorn, PhD
Journal topoi
Year 2017
DOI
10.1097/TXD.0000000000000734
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.