removal of arsenic from groundwater with low cost multilayer media
Clicks: 413
ID: 147288
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
66.9
/100
413 views
286 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #1 of 24 articles by views in g3 (bethesda, md)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple, low cost arsenic removal system was developed to treat arsenic contaminated ground water containing 425 ± 4.2 µg/L arsenic. The system decontaminates arsenic from water by sorption through fine particles of waste materials (Coconut husk’s ash, Refused brick dust, Stone dust and Waste newspaper) of multilayer. The treatment efficiency of the process was investigated under various operating conditions that might affect the sorption/ desorption of arsenic. Sorption column method shows the optimum removal of As(III) under the following conditions: initial As concentration (100 µg/L), sorbent amount (4.0 g for brick dust, 3.0 g for stone dust, 3.0 g for Coconut husk’s ash and 0.3 g for waste newspaper), particle size (<355 µm), treatment flow rate (1.4 mL/min), optimum volume (100 mL) and pH (5.0). Desorption efficiencies with 2M of KOH after the treatment of groundwater were observed in the range of 78 ± 1.2% - 82 ± 1.4%. Average arsenic concentration of treated sample water was 8.30 ± 0.4 µg/L which is below the WHO guideline value for Bangladesh. Different techniques were used to measure thirteen metals, four anions with pH, conductivity, and temperature to understand the status of other species before and after treatment. The average concentrations of other inorganic constituents of health concern (Cu, Mn, Pb, Cr and Fe) in treated water were below WHO guideline value for drinking water. The present study showed a new method for removal of as from ground water.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (109 words).
Try re-searching for a better abstract.
| Reference Key |
samad2010pakistanremoval
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Abdus Samad;Mohammad Arifur Rahman;A. M. Shafiqul Alam* |
| Journal | g3 (bethesda, md) |
| Year | 2010 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.