updated smithsonian astrophysical observatory ozone monitoring instrument (sao omi) formaldehyde retrieval
Clicks: 205
ID: 147259
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
205 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #53 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
We present and discuss the Smithsonian Astrophysical Observatory (SAO)
formaldehyde (H2CO) retrieval algorithm for the Ozone Monitoring
Instrument (OMI) which is the operational retrieval for NASA OMI H2CO. The
version of the algorithm described here includes relevant changes with
respect to the operational one, including differences in the reference
spectra for H2CO, the fit of O2–O2 collisional complex, updates in
the high-resolution solar reference spectrum, the use of a model reference
sector over the remote Pacific Ocean to normalize the retrievals, an updated
air mass factor (AMF) calculation scheme, and the inclusion of scattering
weights and vertical H2CO profile in the level 2 products. The setup of
the retrieval is discussed in detail. We compare the results of the updated
retrieval with the results from the previous SAO H2CO retrieval. The
improvement in the slant column fit increases the temporal stability of the
retrieval and slightly reduces the noise. The change in the AMF calculation
has increased the AMFs by 20%, mainly due to the consideration of the
radiative cloud fraction. Typical values for retrieved vertical columns are
between 4 × 1015 and
4 × 1016 molecules cm−2, with typical fitting
uncertainties ranging between 45 and 100%. In high-concentration regions
the errors are usually reduced to 30%. The detection limit is estimated at
1 × 1016 molecules cm−2.
| Reference Key |
abad2015atmosphericupdated
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;G. González Abad;X. Liu;K. Chance;H. Wang;T. P. Kurosu;R. Suleiman |
| Journal | bioorganic & medicinal chemistry |
| Year | 2015 |
| DOI |
10.5194/amt-8-19-2015
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments