In Situ Growing of Triethanolamine-Functionalized Metal-Organic Frameworks on 2D Carbon Nanosheets for Electrochemiluminescent Immunoassay.

Clicks: 350
ID: 14654
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #8 of 42 articles by views in ACS sensors

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A facile strategy for in-situ growing triethanolamine (TEOA)-functionalized metal-organic framework (TEOA@MOF) on the 2D graphene oxide (GO) or g-C3N4 nanosheets via the self-assembly technique was introduced. In this method, Zn2+ was firstly attached on the carbon nanosheets by electrostatic interaction, then trimesic acid (H3btc) acted as the complex agent and TEOA as a base for the deprotonation of H3btc and a template, which leads to in situ growing the MOF on the carbon nanosheets obtaining a sandwich-like structure. Different types of surface analysis techniques were employed to characterize the GO-TEOA@MOFs and g-C3N4-TEOA@MOFs nanomaterials fabricated. The GO-TEOA@MOFs or g-C3N4-TEOA@MOFs nanomaterials modified electrode brings out obviously enhanced ECL behaviors due to numerous TEOA in the framework structures. Specifically, both TEOA and GO can serve as the co-reactants for ECL system of Ru(bpy)32+ and have the synergic effect of enhancing signal. Based on the GO-TEOA@MOFs modified electrodes, we developed a sensitive and rapid label-free ECL immunoassay strategy for human copeptin, and the linear range was 5 pg mL-1 ‒500 ng mL-1 as well as the limit of detection was 360 fg mL-1. This work exhibits excellent specificity and good stability of prepared immunosensor in the practical sample determination, demonstrating it can serve as a very promising method for the clinical diagnostics of acute myocardial infarction (AMI) disease.
Reference Key
qin2019inacs Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Qin, Xiaoli;Dong, Yifan;Wang, Minghan;Zhu, Zhiwei;Li, Meixian;Yang, Di;Shao, Yuanhua;
Journal ACS sensors
Year 2019
DOI
10.1021/acssensors.9b00914
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.