instrumented wireless smartinsole system for mobile gait analysis: a validation pilot study with tekscan strideway

Klicks: 396
ID: 146483
2018
Artikelqualität & Leistungskennzahlen
Gesamtqualität
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
KI-Qualitätsbewertung
Nicht analysiert
Readership in this journal
Emerging

Ranked #4 of 17 articles by views in agronomía colombiana

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A SmartInsoles Cyber-Physical System (CPS) is designed and implemented for the purpose of measuring gait parameters of multiple users in a restriction-free environment. This CPS comprises a master software installed on a computer and numerous multi-sensory health devices in the form of smart insoles. Each of these insoles contains 12 Force-Sensitive Resistor (FSR) sensors, an Inertial Measurement Unit (IMU), a WiFi-enabled microcontroller and a battery to power all components. A validation pilot study was completed in collaboration with the Interdisciplinary School of Health Sciences at the University of Ottawa by performing 150 trials on 15 healthy subjects. Each subject performed 10 walks on the Tekscan Strideway gait mat system, while simultaneously wearing the designed SmartInsoles CPS. Spatiotemporal data for over 450 unique steps were collected by both systems. These data were analyzed carefully, and a thorough comparison was performed between the results from the two systems. Seven parameters were analyzed in this study: stride time, stance time, swing time, double support time, step time, cadence and gait time. Detailed results in the form of tables, scatterplots, histograms and Bland–Altman graphs were generated. Analysis of the results shows high agreement between the values of the two systems and suggests high accuracy of the implemented CPS as a multi-device, multi-sensory system for gait measurement and analysis.
Referenzschlüssel
arafsha2018journalinstrumented Verwenden Sie diesen Schlüssel zum automatischen Zitieren im Manuskript bei Verwendung von SciMatic Manuscript Manager oder Thesis Manager
Autoren ;Faisal Arafsha;Christina Hanna;Ahmed Aboualmagd;Sarah Fraser;Abdulmotaleb El Saddik
Zeitschrift agronomía colombiana
Jahr 2018
DOI
10.3390/jsan7030036
URL
Schlüsselwörter

Zitationen

Keine Zitationen gefunden. Um eine Zitation hinzuzufügen, kontaktieren Sie den Administrator unter info@scimatic.org

Noch keine Kommentare. Seien Sie der Erste, der diesen Artikel kommentiert.