research on the neutral-point voltage balance for npc three-level inverters under non-ideal grid conditions
Clicks: 74
ID: 145891
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
21.9
/100
74 views
20 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #505 of 526 articles by views in acs combinatorial science
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In order to solve the neutral-point voltage unbalancing problem for neutral-point clamped (NPC) three-level inverters under non-ideal grid conditions, a novel zero-sequence component injection method for modulation signals was proposed in this paper. Based on the mathematical expressions of neutral-point voltage unbalancing, the fluctuation of the neutral-point voltage under different grid conditions was studied. The proposed method dynamically calculates the zero-sequence component for modulation signals by region selections based on sinusoidal pulse width modulation (DCR-SPWM). Under non-ideal grid conditions, this DCR-SPWM method can control the neutral-point voltage balance for NPC three-level inverters with different grid and output power conditions, and improves the grid current quality. The simulation results verified the correctness of the theoretical analysis in this paper, and the feasibility and effectiveness of this method were verified by the experiments in the experimental platform of the NPC three-level grid-connected inverter based on DSP-CPLD controllers.
| Reference Key |
lyu2018energiesresearch
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Jian Guo Lyu;Ji Dong Wang;Wen Bin Hu;Zhao Feng Wu |
| Journal | acs combinatorial science |
| Year | 2018 |
| DOI |
10.3390/en11061331
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org