The influence of the waste matrix heterogeneity on the flux density value of initial gamma quanta at the transport of quanta in the matrix was considered. It is shown that the waste heterogeneity leads to the positive shift of the average flux density value comparing with corresponding value for homogeneous waste if average value of the attenuation factor
in heterogeneous matrix is equal to the attenuation factor of homogeneous matrix. Due to this the activity assay of
heterogeneous waste by a technique which was calibrated by using a homogeneous standard (surrogate container) the
measurement results will be positively shifted, or, in other words, conservative estimation of the waste activity will be obtained.
| Reference Key |
prokopenko2009onderna
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Prokopenko, V. S.;Saltykov, L. S.;Slisenko, V. I.;Shevchenko, S. V.;Kozhushko, B. V.; |
| Journal | Âderna fìzika ta energetika |
| Year | 2009 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.