preparation and characterization of vancomycin-loaded electrospun rana chensinensis skin collagen/poly(l-lactide) nanofibers for drug delivery

Clicks: 155
ID: 144307
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #249 of 443 articles by views in reproductive biology and endocrinology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 443 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Collagen was extracted from abandoned Rana chensinensis skin in northeastern China via an acid enzymatic extraction method for the use of drug carriers. In this paper we demonstrated two different nanofiber-vancomycin (VCM) systems, that is, VCM blended nanofibers and core-shell nanofibers with VCM in the core. Rana chensinensis skin collagen (RCSC) and poly(L-lactide) (PLLA) (3 : 7) were blended in 1,1,1,3,3,3-hexafluoroisopropanol (HFIP) at a concentration of 10% (g/mL) to fabricate coaxial and blend nanofibers, respectively. Coaxial and blend electrospun RCSC/PLLA nanofibers containing VCM (5 wt%) were evaluated for the local and temporal delivery of VCM. The nanofiber scaffolds were characterized by environmental scanning electron microscope (ESEM), transmission electron microscopy (TEM), Fourier transform infrared spectra (FTIR), differential scanning calorimeter (DSC), water contact angle (WCA), and mechanical tests. The drug release of VCM in these two systems was compared by using UV spectrophotometer. The empirical result indicated that both the blend and coaxial RCSC/PLLA scaffolds followed sustained control release for a period of 80 hours, but the coaxial nanofiber might be a potential drug delivery material for its better mechanical properties and sustained release effect.
Reference Key
zhang2016journalpreparation1 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Mei Zhang;Ziqi Li;Lihua Liu;Zhouyang Sun;Wendi Ma;Zhichao Zhang;Rui Zhang;Dahui Sun
Journal reproductive biology and endocrinology
Year 2016
DOI
10.1155/2016/9159364
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.