analysis of low dose level volumes in intensity modulated radiotherapy and 3-d conformal radiotherapy

Clicks: 161
ID: 142673
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract

Purpose: To analyze the low dose volume regions in four facets: Analysis 1: low dose volume regions were compared between 3-dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) plans for each case; Analysis 2: the effect on low dose volume in 3DCRT as the number of fields are increased; Analysis 3: the same effect in IMRT, and Analysis 4: above two analysis were inter-compared between the two modalities.

Methods: For this work 18 patients were taken for which both 3DCRT and IMRT plans with varying number of beams were planned using Anisotropic Analytical Algorithm (AAA) in Eclipse 10 Version Treatment Planning System with two to nine beams and five to nine beams, respectively. The plans were analyzed on the basis of conformity index and dose to the critical structures.

Results: In Analysis 1, 5 Gy volume region was greater for IMRT than for 3DCRT but the 10 Gy, 15 Gy and 20 Gy volume regions were smaller for IMRT plans. In Analysis 2 and 3 shows that as the number of fields increases the low dose volume regions also increases. In Analysis 4, the effect pronounced due to increase in the beam portals is similar in 3DCRT as well as IMRT. Also it was seen that with same number of beams for both IMRT and 3DCRT, low dose volume region is higher in 3DCRT than IMRT.

Conclusion: Low dose volume regions are a major concern in 3DCRT and IMRT plans with multiple beams because of its risk of secondary cancer incidence. This study concludes that by increasing number of beams low dose volume regions increases in 3DCRT and IMRT. It shows that the low dose volume regions are slightly higher in IMRT than 3DCRT, however with proper optimization the volume of tissue receiving 10 Gy, 15 Gy and 20 Gy can be reduced.

-----------------------

Cite this article as: Ekambaram V, Velayudham R. Analysis of low dose level volumes in intensity modulated radiotherapy and 3-D conformal radiotherapy. Int J Cancer Ther Oncol 2014; 2(3):02032. DOI: 10.14319/ijcto.0203.2

Reference Key
ekambaram2014internationalanalysis Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Varadharajan Ekambaram;Ramasubramanian Velayudham
Journal international journal of cancer therapy and oncology
Year 2014
DOI
10.14319/ijcto.0203.2
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.