dynamics verification experiment of the stewart parallel manipulator
Clicks: 312
ID: 142623
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
312 views
46 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #6 of 10 articles by views in thai journal of obstetrics and gynaecology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
As the basis of dynamic analysis and driving force calculation, dynamic models and dynamic parameters are important issues in mechanical design and control. In this paper, a dynamics verification experiment, which covers both dynamic models and dynamic parameters as a whole, is carried out on the typical Stewart parallel manipulator. First, the complete dynamic model of the Stewart manipulator is derived, considering the force sensors. The Newton-Euler method with clear physical meaning is adopted to facilitate understanding and parameter definitions. The dynamic parameters are deduced based on the established three-dimensional virtual prototype and adjusted with actual measurements. The recorded trajectory, instead of the theory trajectory, is adopted to calculate the theoretical limb forces. The practical limb forces are measured using pull pressure sensors. Finally, the dynamic model and identified parameters are verified by comparing the limb forces obtained using the above two approaches. Experiment results show that theoretical and practical limb forces coincide well, with a small maximum RMS (root mean square) error of 1.516N and forces ranging from 10N to 40N. Additionally, the established dynamics verification algorithm, which involves dynamic modelling, a parameter identification approach and a data analysis method, are generic and practical, and can be flexibly applied to the dynamic analysis of other parallel manipulators.
| Reference Key |
shao2015internationaldynamics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Zhu-Feng Shao;Xiaoqiang Tang;Liping Wang |
| Journal | thai journal of obstetrics and gynaecology |
| Year | 2015 |
| DOI |
10.5772/61541
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org