quantitative determination and validation of metformin hydrochloride in pharmaceutical using quantitative nuclear magnetic resonance spectroscopy
Clicks: 265
ID: 142322
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
265 views
59 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #42 of 235 articles by views in Journal of pharmaceutical and biomedical analysis
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Rapid, specific and accurate proton nuclear magnetic resonance spectroscopy (1H NMR) method was developed to determine metformin hydrochloride antidiabetic drug in pharmaceutical tablet formulation. The method was based on quantitative NMR spectroscopy (qNMR) using maleic acid as an internal standard and deuterium oxide (D2O) as a diluent. For the quantification of the drug, the (1H NMR signals at 2.91 ppm and 6.25 ppm corresponding to the analyte proton of metformin hydrochloride and maleic acid internal reference standard (IS) respectively were used. The method was validated for the parameters of specificity and selectivity, precision and intermediate precision, linearity, range, limit of detection (LOD) and limit of quantification (LOQ), accuracy, solution stability and robustness. The linearity of the calibration curve for analyte in the desired concentration range was good (R2=0.9993). The method was accurate and precise with good recoveries. Range study was also performed up to saturation level (152.67 mg/0.60 mL) in D2O. The advantage of the method is that no reference standard of analyte drug is required for quantification. The method is nondestructive and can be applied for quantification of metformin hydrochloride in commercial formulation products.
| Reference Key |
gadape2011e-journalquantitative
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;H. H. Gadape;K. S. Parikh |
| Journal | Journal of pharmaceutical and biomedical analysis |
| Year | 2011 |
| DOI |
10.1155/2011/461898
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org