copper nano-clusters prepared by one-step electrodeposition and its application on nitrate sensing
Clicks: 251
ID: 141664
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
251 views
41 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #5 of 51 articles by views in journal of hydrology: x
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper describes the fabrication and characterization of copper nano-clusters prepared by a simple one-step electrodeposition process on platinum microelectrode, and the application for nitrate determination. The one-step electrodepostion process was performed by chronoamperometry scan in acidic copper sulphate electrolyte directly. The SEM and electrochemical examination showed that the morphologies and microstructures of deposited copper layers can be precisely controlled by using different deposition voltages. It was found that the copper layer is porous when the deposition voltage is higher than -500 mV, and this porous layer has a larger effective surface area compared with the corresponding smooth flat copper layer deposited under voltage less than -300 mV. Under the optimized deposition voltage, copper clusters constructed by uniform nanoparticles with an average diameter of about 100 nm can be obtained. The mechanism of electrodeposition process for this method was also speculated. The copper layers deposited under different voltages are used in a series of tests in order to evaluate their performance for nitrate sensing. The experimental results reveal that the microelectrode modified by fixed potential deposition under -700 mV had a higher sensitivity of 39.31 μA/mmolL−1 for nitrate detection within the concentration ranging from 0.1 mmolL−1 to 4.0 mmolL−1.
| Reference Key |
li2015aipcopper
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Y. Li;J.Z. Sun;C. Bian;J.H. Tong;H.P. Dong;H. Zhang;S.H. Xia |
| Journal | journal of hydrology: x |
| Year | 2015 |
| DOI |
10.1063/1.4905712
|
| URL | |
| Keywords |
Citations