Abstract
Background
The purpose of this study was to assess the concurrent validity of alternative measures of frontal plane knee alignment, namely the radiographic anatomic axis and two clinical measures in patients complaining of knee malalignment as compared with the mechanical axis on full-length radiograph of lower limbs.
Methods
The knee-alignment angle was measured in 100 knees of 50 subjects with the chief complaint of frontal knee malalignment according to the following methods: lower-limb mechanical axis on radiograph, lower-limb anatomic axis on radiograph, distance between medial femoral condyles or medial malleoli using a calliper and lower-limb alignment using a goniometer. Data were analyzed using Pearson’s correlation coefficient and simple linear regression.
Results
The anatomic axis best correlated with the mechanical axis (r = 0.93, P<0.001), followed closely by the intercondylar/intermalleolar distance measured by calliper (r = 0.89, P<0.001). Significant correlation was also found between the mechanical-axis angle and the lower limb axis measured by goniometer (r = 0.67, P<0.001).
Conclusions
The anatomic axis on radiograph, the calliper method and to a lesser extent the goniometer measurement appear to be valid alternatives to the mechanical axis on full-leg radiograph for determining frontal plane knee alignment. These alternative measures have the potential to provide useful information regarding knee alignment and may increase the assessment of this parameter by clinicians and researchers.
| Reference Key |
m2012sportsa
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Navali Amir M;Bahari Leila Azhar;Nazari Behrouz |
| Journal | sports medicine, arthroscopy, rehabilitation, therapy & technology |
| Year | 2012 |
| DOI |
10.1186/1758-2555-4-40
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.