on variable reverse power flow-part i: active-reactive optimal power flow with reactive power of wind stations

Clicks: 68
ID: 140522
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #510 of 526 articles by views in acs combinatorial science

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
It has recently been shown that using battery storage systems (BSSs) to provide reactive power provision in a medium-voltage (MV) active distribution network (ADN) with embedded wind stations (WSs) can lead to a huge amount of reverse power to an upstream transmission network (TN). However, unity power factors (PFs) of WSs were assumed in those studies to analyze the potential of BSSs. Therefore, in this paper (Part-I), we aim to further explore the pure reactive power potential of WSs (i.e., without BSSs) by investigating the issue of variable reverse power flow under different limits on PFs in an electricity market model. The main contributions of this work are summarized as follows: (1) Introducing the reactive power capability of WSs in the optimization model of the active-reactive optimal power flow (A-R-OPF) and highlighting the benefits/impacts under different limits on PFs. (2) Investigating the impacts of different agreements for variable reverse power flow on the operation of an ADN under different demand scenarios. (3) Derivation of the function of reactive energy losses in the grid with an equivalent-π circuit and comparing its value with active energy losses. (4) Balancing the energy curtailment of wind generation, active-reactive energy losses in the grid and active-reactive energy import-export by a meter-based method. In Part-II, the potential of the developed model is studied through analyzing an electricity market model and a 41-bus network with different locations of WSs.
Reference Key
gabash2016energieson Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Aouss Gabash;Pu Li
Journal acs combinatorial science
Year 2016
DOI
10.3390/en9030121
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.