Stability Improvement of Power System due to Wind Farm and Fault using FACTS Devices

Klik: 378
ID: 13922
2018
PDF Gratis
Metrik Kualitas & Kinerja Artikel
Kualitas Keseluruhan
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
Penilaian Kualitas AI
Belum dianalisis
Readership in this journal
Steady

Ranked #14 of 46 articles by views in adbu journal of electrical and electronics engineering (ajeee)

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstrak
Wind energy is gaining the most interest among a variety of renewable energy resources, but the disadvantage is that wind power generation is intermittent, depending on weather conditions. FACTS devices are used to increase the transient stability on the presence of faults and the integration of renewable sources, like wind energy. Due to continuously varying wind speed components and also due to fault the active and reactive power along with terminal voltage fluctuates continuously. STATCOM and UPFC are two important FACTS devices; provide the desired reactive-power generation and absorption, entirely using electronic processing of the voltage and current waveforms in a voltage source converter (VSC). By connecting STATCOM and UPFC into the lines, the active power, reactive power, and terminal voltage is maintained constant and it also helps to improve the transient stability of the system. STATCOM can control voltage magnitude and, to a small extent, the phase angle in a very short time and UPFC can control voltage magnitude as well as phase angle and therefore, can improve the system performance. In this paper, improvement of transient stability in wind farm under fault have been studied using STATCOM and UPFC in MATLAB SIMULINK software.
Kunci Referensi
thabah2018stabilityadbu Gunakan kunci ini untuk mengutip otomatis dalam naskah saat menggunakan SciMatic Manuscript Manager atau Thesis Manager
Penulis
Jurnal adbu journal of electrical and electronics engineering (ajeee)
Tahun 2018
DOI
DOI tidak ditemukan
URL
Kata Kunci

Sitasi

Tidak ada sitasi yang ditemukan. Untuk menambahkan sitasi, hubungi admin di info@scimatic.org

Belum ada komentar. Jadilah yang pertama berkomentar pada artikel ini.