Stability Improvement of Power System due to Wind Farm and Fault using FACTS Devices
Clicks: 330
ID: 13922
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
71.3
/100
330 views
224 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #17 of 46 articles by views in adbu journal of electrical and electronics engineering (ajeee)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Wind energy is gaining the most interest among a variety of renewable energy resources, but the disadvantage is that wind power generation is intermittent, depending on weather conditions. FACTS devices are used to increase the transient stability on the presence of faults and the integration of renewable sources, like wind energy. Due to continuously varying wind speed components and also due to fault the active and reactive power along with terminal voltage fluctuates continuously. STATCOM and UPFC are two important FACTS devices; provide the desired reactive-power generation and absorption, entirely using electronic processing of the voltage and current waveforms in a voltage source converter (VSC). By connecting STATCOM and UPFC into the lines, the active power, reactive power, and terminal voltage is maintained constant and it also helps to improve the transient stability of the system. STATCOM can control voltage magnitude and, to a small extent, the phase angle in a very short time and UPFC can control voltage magnitude as well as phase angle and therefore, can improve the system performance. In this paper, improvement of transient stability in wind farm under fault have been studied using STATCOM and UPFC in MATLAB SIMULINK software.
| Reference Key |
thabah2018stabilityadbu
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Julene Seka H. Thabah;Darihun Sawkmie;Maitshaphrang Lyngdoh;Smriti Dey; |
| Journal | adbu journal of electrical and electronics engineering (ajeee) |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.