Optimal operation of Distributed Network embedded to wind – Battery storage system for revenue enhancement
Clicks: 261
ID: 13796
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
64.5
/100
261 views
214 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #40 of 148 articles by views in adbu journal of engineering technology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 148 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The environmental concerns and the fuel cost uncertainties associated with the conventional energy sources consequently lead to rapid growth of renewable energy sources connected to the distribution grids. Moreover the continuous increase of power demand emphasizes more and more integration of renewable generation units to the power network to supply the required demand. This incorporation of the distributed generation into the distributed network has tremendous potential if it can be used properly. But the installation cost of these plants are very high. Thus to balance the cost incurred while installing the plant the revenue from those renewable energy producers have to be maximized and losses are to be minimized by using dynamic optimization techniques. The main aim of the project work is to find the optimal operation or condition of a distribution system when embedded to a wind- battery storage system. Hence this paper presents the operation of Particle Swarm Optimization which provides an optimal strategy to increase the revenue from the power trading to the network. Results of IEEE 14 bus system is presented.
| Reference Key |
hazarika2018optimaladbu
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Swapnali Hazarika;Smriti Dey; |
| Journal | adbu journal of engineering technology |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.