Power Quality Enhancement in Wind Power Generation Integrated Distribution System using Fuzzy Logic Controlled CSC Based DVR
Clicks: 288
ID: 13795
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
78.8
/100
288 views
233 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #21 of 148 articles by views in adbu journal of engineering technology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 148 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this paper, a model of fuzzy logic controlled CSC based DVR system has been proposed with the objective of performing voltage regulation and harmonics reduction tasks simultaneously in a power distribution system. The distribution system is integrated with a standalone renewable energy source (RES) driven i.e. wind power generation system based on self excited induction generator (SEIG) supplying power to customers having a variety of loads. For power quality (PQ) enhancement in electric power distribution systems, the custom power devices (CPDs) designed with conventional controllers such as proportional- integral (PI), proportional-integral-derivative (PID) etc. are widely used. The objective of using CPD is to mitigate the PQ problems encountered in the power distribution system that includes short and long duration voltage variations, voltage imbalance, waveform distortions etc. Amongst the various types of CPDs, the dynamic voltage restorer (DVR) is considered to be one of the versatile CPD capable of solving multiple PQ problems. In most of the literatures, the DVR is found to be designed and implemented with voltage source converter (VSC) topology and not much research work has been reported on the application of current source converter (CSC) topology in DVR system over the last couple of decades. The proposed CSC based model has been simulated using MATLAB / Simulink for investigating its performance. The simulation results support the validity of the proposed model.
| Reference Key |
singh2018poweradbu
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | M.Deben Singh;R. K. Mehta;A. K. Singh; |
| Journal | adbu journal of engineering technology |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.