comparison of nd:yag laser posterior capsulotomy techniques: cruciate versus circular

Clicks: 301
ID: 137945
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #4 of 8 articles by views in african renaissance

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND AND OBJECTIVE: Nd:YAG laser posterior capsulotomy is a standard method for treatment of posterior capsule opacification (PCO) in adults. However, there is not enough information available regarding the advantages and disadvantages of its conventional techniques. This study aims to compare cruciate and circular techniques of Nd: YAG laser posterior capsulotomy. METHODS: In this clinical trial, 100 eyes of patients with posterior capsule opacification after cataract surgery were randomly divided into two groups. Cruciate capsulotomy was performed for the first group and circular capsulotomy was performed for the second group. Visual acuity, intraocular pressure, lens shifting, uveitis, macular hole and retinal detachment were examined. In addition, the energy used for rupturing the capsule was recorded. IRCT: 201207037466N4. FINDINGS: The energy used in circular capsulotomy (345±68.53) was significantly more than the energy used in cruciate capsulotomy (284.4±46.78) (p=0.001). Results showed that there is no significant difference between the two groups in terms of average visibility (p=0.859) and intraocular pressure (p=0.097). Nevertheless, these two variables increase significantly through time (p=0.001). Moreover, there is no significant difference between the two groups in terms of percentage of halo. CONCLUSION: Since improvement in visual acuity and intraocular pressure was similar in the two groups but the energy used in circular capsulotomy was more than cruciate capsulotomy, cruciate technique is the preferred method.
Reference Key
rezaei2016majallah-icomparison Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;R Rezaei;A Almasi-Hashiani;M Khorrambakht;A Khosravi
Journal african renaissance
Year 2016
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.