a simple semipaced 3-minute chair rise test for routine exercise tolerance testing in copd
Clicks: 90
ID: 137941
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
26.7
/100
90 views
11 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #75 of 88 articles by views in tijdschrift voor geneeskunde
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Bernard Aguilaniu,1,2 Hubert Roth,3 Jesus Gonzalez-Bermejo,4 Marie Jondot,5 Jocelyne Maitre,5 François Denis,6 Thomas Similowski4,7 1Medicine Faculty, Université Joseph Fourier, Grenoble, France; 2McGill University, Montreal, Canada; 3Centre de Recherche en Nutrition Humaine Rhône-Alpes, CHU Grenoble, France; 4Assistance Publique-Hôpitaux de Paris, Groupe Hospitalier Pitié-Salpêtrière, Respiratory and Intensive Care Medicine, Paris, France; 5Clinique Universitaire de Pneumologie, CHU Grenoble, France, Grenoble, France; 6Boehringer Ingelheim, 7Université Paris, Paris, France Abstract: The functional work capacity of chronic obstructive pulmonary disease (COPD) patients is usually assessed with walk tests such as the 6-minute walk test (6MWT) or the shuttle test. Because these exercise modalities require a controlled environment which limits their use by pulmonologists and severely restricts their use among general practitioners, different modalities of a short (1 minute or less) sit-to-stand test were recently proposed. In this study, we evaluated a new modality of a semipaced 3-minute chair rise test (3CRT) in 40 patients with COPD, and compared the reproducibility of physiological responses and symptoms during the 3CRT and their interchangeability with the 6MWT. The results demonstrate that physiological variables, heart rate, pulse oxygen saturation, work done, and symptoms (Borg dyspnea and fatigue scores), during the 3CRT were highly reproducible, and that the physiological responses and symptoms obtained during the 3CRT and the 6MWT were interchangeable for most patients. Moreover, these preliminary data suggest that patients able to perform more than 50 rises during 3 minutes had no significant disability. The simplicity and ease of execution of the 3CRT will facilitate the assessment of exercise symptoms and disability in COPD patients during routine consultations with pulmonologists and general practitioners, and will thus contribute to the improved management of COPD patients.Keywords: exercise test, disability, routine monitoring, chair test
| Reference Key |
b2014internationala
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Aguilaniu B;Roth H;Gonzalez-Bermejo J;Jondot M;Maitre J;Denis F;Similowski T |
| Journal | tijdschrift voor geneeskunde |
| Year | 2014 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.