oscillating positive airway pressure (o-pap) versus cpap for the treatment of obstructive sleep apnea

Clicks: 288
ID: 137907
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #40 of 82 articles by views in Stroke

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Although continuous positive airway pressure (CPAP) is the most effective therapy for obstructive sleep apnea, it is not always well tolerated by the patients. Previous physiological studies showed that pressure oscillations applied to the pharynx could activate upper airway muscles, but it is not clear whether these pressure oscillations could be tolerated during sleep in obstructive sleep apnea (OSA) patients. The aim of this study was to assess the tolerance of O-PAP (a CPAP device delivering high-frequency pressure oscillations to the upper airway) compared to CPAP. 14 OSA patients currently on CPAP (age 59.9±10.1 y.o., BMI 34.8±7.2 kg/m2, initial AHI: 58.7±25.2 events/hour) used O-PAP or CPAP on two consecutive nights under polysomnography, in a single-blind randomized crossover design to assess sleep quality. A subtherapeutic pressure (70% of the optimal titrated pressure) was applied in both conditions and the residual apnea-hypopnea index (AHI) with each technique was also compared. There was no difference in measured or perceived sleep quality between the two treatment modalities (Sleep efficiency 90.0% vs 88.1%, p= 0.54). Despite the small sample, we also found a trend toward a decrease in residual respiratory events with O-PAP compared to CPAP (median AHI 14.3 vs 20.5/h, p=0.194). The good tolerance of O-PAP and the positive trend toward a reduction in residual AHI should stimulate further research on the effects of O-PAP in OSA patients.
Reference Key
ehaba-rubio2015frontiersoscillating Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;JOSE eHABA-RUBIO;Nicolas Julien Petitpierre;Françoise eCornette;Nadia eTobback;Sopharat eVat;Theresia eGiallourou;AHMED eAL-JUMAILY;Raphael eHeinzer
Journal Stroke
Year 2015
DOI
10.3389/fmed.2015.00029
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.