designing an experiment to investigate subpixel mapping as an alternative method to obtain land use/land cover maps

Clicks: 303
ID: 137728
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #105 of 499 articles by views in Journal of pharmacological sciences

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 499 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Various subpixel mapping (SPM) methods have been proposed as downscaling techniques to reduce uncertainty in classifying mixed pixels. Such methods can provide category maps of a higher spatial resolution than the original input images. The aim of this study was to explore and validate the potential of SPM as an alternative method for obtaining land use/land cover (LULC) maps of regions where high-spatial-resolution LULC maps are unavailable. An experimental design was proposed to evaluate the feasibility of SPM for providing the alternative LULC maps. A case study was implemented in the Jingjinji region of China. SPM results for spatial resolutions of 500–100 m were derived from a single 1-km synthetic fraction image using two representative SPM methods. The 1-km synthetic fraction image was assumed to be error free. Accuracy assessment and analysis showed that overall accuracies of the SPM results were reduced from about 85% to 75% with increasing spatial resolution, and that producer’s accuracies varied considerably from about 62% to 93%. SPM performed best when handling areal features in comparison with linear and point features. The highest accuracies were achieved for areas with the lowest complexity. The study concluded that the results from SPM could provide an alternative LULC data source with acceptable accuracy, especially in areas with low complexity and with a large proportion of areal features.
Reference Key
ge2016remotedesigning Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Yong Ge;Yu Jiang;Yuehong Chen;Alfred Stein;Dong Jiang;Yuanxin Jia
Journal Journal of pharmacological sciences
Year 2016
DOI
10.3390/rs8050360
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.