parameters that affect electricity consumption in fish freezing. case study

Clicks: 326
ID: 137687
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1 of 4 articles by views in bruno pini mathematical analysis seminar

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Reducing energy consumption in industry has become an important aspect on a global scale. Energy efficiency is one way of reducing energy consumption and promoting competitiveness. Increasing energy costs, security of energy supply, emissions from energy production have shown that current freezer design solutions are not sustainable. The food industry has a common tendency, whereby energy costs are only of secondary importance, unlike other production costs, resulting in minimal monitoring of energy consumption. Electricity consumption for freezer operation amounts to 20 % of total electricity consumption. Within the framework of this study, electricity consumption for fish freezing and storing frozen fish and finished products, as well as the coefficient of performance (COP) for compressors and parameters affecting COP were analyzed. From the results it can be concluded that the specific consumption of electricity in freezing of fish is lower than that of frozen fish storage. The two-stage compressor COP ranges from 2.4 to 3.7, but the single-stage compressor COP ranges from 3.7 to 5.5. The pressure in the condenser and ammonia vapor temperature after the compressor is affected by the temperature of the water used to cool the condenser and compressors. As the temperature of the water used for cooling increases, the condenser and ammonia vapor temperature after the compressor increase, which in turn reduces the compressor COP.
Reference Key
edvins2019environmentalparameters Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Terehovics Edvins;Veidenbergs Ivars;Blumberga Dagnija
Journal bruno pini mathematical analysis seminar
Year 2019
DOI
10.2478/rtuect-2019-0076
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.