Simultaneous reconstruction of multiple stiff wires from a single X-ray projection for endovascular aortic repair.

Clicks: 341
ID: 13728
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #6 of 19 articles by views in international journal of computer assisted radiology and surgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Endovascular repair of aortic aneurysms (EVAR) can be supported by fusing pre- and intraoperative data to allow for improved navigation and to reduce the amount of contrast agent needed during the intervention. However, stiff wires and delivery devices can deform the vasculature severely, which reduces the accuracy of the fusion. Knowledge about the 3D position of the inserted instruments can help to transfer these deformations to the preoperative information.We propose a method to simultaneously reconstruct the stiff wires in both iliac arteries based on only a single monoplane acquisition, thereby avoiding interference with the clinical workflow. In the available X-ray projection, the 2D course of the wire is extracted. Then, a virtual second view of each wire orthogonal to the real projection is estimated using the preoperative vessel anatomy from a computed tomography angiography as prior information. Based on the real and virtual 2D wire courses, the wires can then be reconstructed in 3D using epipolar geometry.We achieve a mean modified Hausdorff distance of 4.2 mm between the estimated 3D position and the true wire course for the contralateral side and 4.5 mm for the ipsilateral side.The accuracy and speed of the proposed method allow for use in an intraoperative setting of deformation correction for EVAR.
Reference Key
breininger2019simultaneousinternational Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Breininger, Katharina;Hanika, Moritz;Weule, Mareike;Kowarschik, Markus;Pfister, Marcus;Maier, Andreas;
Journal international journal of computer assisted radiology and surgery
Year 2019
DOI
10.1007/s11548-019-02052-7
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.