Simultaneous reconstruction of multiple stiff wires from a single X-ray projection for endovascular aortic repair.
Clicks: 341
ID: 13728
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
72.1
/100
341 views
244 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #6 of 19 articles by views in international journal of computer assisted radiology and surgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Endovascular repair of aortic aneurysms (EVAR) can be supported by fusing pre- and intraoperative data to allow for improved navigation and to reduce the amount of contrast agent needed during the intervention. However, stiff wires and delivery devices can deform the vasculature severely, which reduces the accuracy of the fusion. Knowledge about the 3D position of the inserted instruments can help to transfer these deformations to the preoperative information.We propose a method to simultaneously reconstruct the stiff wires in both iliac arteries based on only a single monoplane acquisition, thereby avoiding interference with the clinical workflow. In the available X-ray projection, the 2D course of the wire is extracted. Then, a virtual second view of each wire orthogonal to the real projection is estimated using the preoperative vessel anatomy from a computed tomography angiography as prior information. Based on the real and virtual 2D wire courses, the wires can then be reconstructed in 3D using epipolar geometry.We achieve a mean modified Hausdorff distance of 4.2 mm between the estimated 3D position and the true wire course for the contralateral side and 4.5 mm for the ipsilateral side.The accuracy and speed of the proposed method allow for use in an intraoperative setting of deformation correction for EVAR.
| Reference Key |
breininger2019simultaneousinternational
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Breininger, Katharina;Hanika, Moritz;Weule, Mareike;Kowarschik, Markus;Pfister, Marcus;Maier, Andreas; |
| Journal | international journal of computer assisted radiology and surgery |
| Year | 2019 |
| DOI |
10.1007/s11548-019-02052-7
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.