[Design and validation of calibration between tube focus spot and center plane of rotation in computed tomography system].
Clicks: 345
ID: 13727
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
69.9
/100
345 views
250 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #2 of 10 articles by views in sheng wu yi xue gong cheng xue za zhi = journal of biomedical engineering = shengwu yixue gongchengxue zazhi
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study proposed a method to calibrate tube focus spot and the center plane of rotation in computed tomography system. In the method, the tube was rotated to 0° and 180° respectively, and then one metal jig with symmetric windows A and B was scanned at each position under the tube cool and static condition. According to the geometry of tube focus spot, aperture center of the collimator and jig, the distance between tube focus spot and the center plane of rotation were calculated with the X ray transmittance data after denoising, mean value and normalization. To verify the practicability and validity of the method, the tube focus spot in a 16 slices CT system (Brivo CT385, GE, China) was calibrated, and the result after calibration was validated by scanning a polaroid film. The validation result showed that the deviation between tube focal spot and center plane of rotation was 0.02 mm and was in the error range within ± 0.1 mm. The results of this study showed that, as a simple and low-cost design, the method could be used for fast calibration between tube focus spot and the center plane of rotation.
| Reference Key |
yu2019designsheng
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yu, Xiaomin;Yin, Wei;Lan, Yu;Liu, Zhihong; |
| Journal | sheng wu yi xue gong cheng xue za zhi = journal of biomedical engineering = shengwu yixue gongchengxue zazhi |
| Year | 2019 |
| DOI |
10.7507/1001-5515.201812016
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.