semiautomatic segmentation of ventilated airspaces in healthy and asthmatic subjects using hyperpolarized he mri

Clicks: 261
ID: 136995
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #16 of 191 articles by views in advanced functional materials

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 191 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A segmentation algorithm to isolate areas of ventilation from hyperpolarized helium-3 magnetic resonance imaging (HP 3He MRI) is described. The algorithm was tested with HP 3He MRI data from four healthy and six asthmatic subjects. Ventilated lung volume (VLV) measured using our semiautomated technique was compared to that obtained from manual outlining of ventilated lung regions and to standard spirometric measurements. VLVs from both approaches were highly correlated (R=0.99; P<0.0001) with a mean difference of 3.8 mL and 95% agreement indices of −30.8 mL and 38.4 mL. There was no significant difference between the VLVs obtained through the semiautomatic approach and the manual approach. A Dice coefficient which quantified the intersection of the two datasets was calculated and ranged from 0.95 to 0.97 with a mean of 0.96 ± 0.01 (mean ± SD). VLVs obtained through the semiautomatic algorithm were also highly correlated with measurements of forced expiratory volume in one second (FEV1) (R=0.82; P=0.0035) and forced vital capacity (FVC) (R=0.95; P<0.0001). The technique may open new pathways toward advancing more quantitative characterization of ventilation for routine clinical assessment for asthma severity as well as a number of other respiratory diseases.
Reference Key
lui2013computationalsemiautomatic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;J. K. Lui;A. S. LaPrad;H. Parameswaran;Y. Sun;M. S. Albert;K. R. Lutchen
Journal advanced functional materials
Year 2013
DOI
10.1155/2013/624683
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.