Štetni faktori u radnim i kontrolnim prostorijama pogona na ratnim brodovima / harmful factors in engine-rooms and machinery control-rooms on warships
Clicks: 131
ID: 136519
2002
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
30.0
/100
131 views
10 readers
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #76 of 103 articles by views in materials chemistry and physics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Na devet ratnih brodova (sedam borbenih i dva pomoćna) RM VJ ispitivani su štetni faktori u motorskim i turbinskim prostorima kao i kontrolnim kabinama motorskog prostora. Utvrđeno je da zaposleni u navedenim prostorima rade u uslovima nedovoljne osvetljenosti, da su izloženi visokoj temperaturi, bud vibracijama, a potencijalno i izduvnim gasovima. Izmereni nivoi buke u motorskim i turbinskim prostorima iznosili su 104-124 dB(A), i bili su znatno iznad dopuštenog nivoa od 85 dB(A), dok je u kontrolnim kabinama većine brodova buka bila ispod nivoa od 80 dB(A). U kontrolnim kabinama dva ratna broda buka je bila iznad dozvoljenog nivoa i iznosila je 83 dB(A) i 95 dB(A). Buka kojoj su izloženi zaposleni u motorskim i turbinskim prostorima može da dovede do oštećenja čula sluha, ukoliko se ne koriste predviđena zaštitna sredstva. / Harmful factors in engine and machinery control rooms on 9 warships (7 combat and 2 auxiliary ships) were examined. The results show that crews on thee sea ships work in conditions of insufficient luminance, elevated air temperature noise, vibration, and possibly are exposed to exhaust gases. The entire noise levels in engine and turbine rooms were between 104 dB(A) and 124 dB(A), and they were significantly above the permissible levels of 85 dB(A) and 80 dB(A). On two ships, in machinery control-rooms, the entire noise was above the permissible level (83 dB(A) and 95 dB(A)). These mentioned noise levels could lead to hearing damage if the self protecting devices for hearing protection are not used.
| Reference Key |
2002vojnotehnikitetni
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Živomir Radojković ;Dejan Živković;Gradimir Basarić |
| Journal | materials chemistry and physics |
| Year | 2002 |
| DOI |
10.5937/vojtehg0202195R
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org