short communication: evaluation of a new rapid diagnostic test for quality assurance by kala azar elimination programme in bangladesh
Clicks: 201
ID: 136478
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
201 views
25 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #19 of 42 articles by views in advances in polymer technology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In Bangladesh, serological tests have been widely used for the primary screening of visceral leishmaniasis (VL). Several serologic tests are available for the diagnosis of VL. Selection of the best test is important to permit diagnostic differentiation between symptomatic and asymptomatic patients and to reduce cross-reactivity. We evaluated the effectiveness of a new serological test “Onsite Leishmania Ab Rapid Test” as a part of “quality assurance” activities for the kala azar elimination programme of the Government of Bangladesh. Plasma samples of 100 parasitologically confirmed cases of VL along with 101 healthy controls were tested, and “Onsite Leishmania Ab Rapid Test” strip tests were positive in 94 out of 100 confirmed VL cases, whereas four out of 51 healthy subjects from the VL endemic areas also tested positive. All the 50 healthy volunteers tested negative. Thus, the sensitivity and specificity of “Onsite Leishmania Ab Rapid Test” strip test were found to be 94% (95% CI: 87–98) and 96% (95% CI: 90–99), respectively. This study showed that the performance of the “Onsite Leishmania Ab Rapid Test” strip tests was up to the recommended level.
| Reference Key |
khan2011journalshort
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Md Gulam Musawwir Khan;Mohammad Shafiul Alam;Abu Toha Bhuiyan;Maleka Arjumand Jamil;Bijoy Saha;Mazharul Islam;Rashidul Haque;Moazzem Hossain;Kazi M. Jamil |
| Journal | advances in polymer technology |
| Year | 2011 |
| DOI |
10.1155/2011/862475
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org