predictors of success of electrical cardioversion for atrial fibrillation

Clicks: 21
ID: 135880
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #28 of 29 articles by views in proceedings - 2009 international conference on future computer and communication, icfcc 2009

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction: Electrical cardioversion is an effective therapeutic procedure to restore sinus rhythm in atrial fibrillation, and its success has been related to different variables. Objective: To relate clinical, electrical and echocardiographic variables to the success of electrical cardioversion for atrial fibrillation and to the amount of energy used to restore sinus rhythm. Method: A prospective longitudinal study was conducted in 82 patients with atrial fibrillation who were treated with elective electrical cardioversion. Results: Electrical cardioversion was successful in 81.7% of patients. Heart failure (p=0.000), mitral valve disease (p=0.001), previous arrhythmic events (p=0.005), increased time to progression (p=0.019), increased left ventricular telediastolic diameter (p=0.000), and increased diameter, area and pressure of the left atrium (p=0.000, p=0.008, p=0.000, respectively), were associated with a decrease in the success of the shock. Left ventricular ejection fraction was the only independent predictor of success (OR 2.1; 95% CI, p=0.048). The use of a higher amount of energy was related to previous arrhythmic events (p=0.000), decreased left ventricular ejection fraction (p=0.000), older age (p=0.037), increased time to progression (p=0.02), increased left ventricular diameter (p=0.000), increased diameter, area and pressure of the left atrium (p=0.000, p=0.000 and p=0.000, respectively) and increased area of the right atrium (p=0.016). Conclusions: The left ventricular ejection fraction is an independent predictor of the success of electrical cardioversion for atrial fibrillation. The presence of biatrial remodeling, left ventricular dysfunction, previous arrhythmic events and a long progression require higher amounts of energy to restore sinus rhythm.
Reference Key
cardentey2016corsaludpredictors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Marleny Cruz Cardentey;Taimara Pérez Rivera;Annerys l Méndez Rosaba