necessity and proper way of intermediate kissing balloon dilation for culotte stenting: further insights from bench testing
Clicks: 214
ID: 135812
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
214 views
44 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 3 articles by views in science education
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objective: The aim of this study was to investigate whether intermediate kissing balloon dilation (IKBD) is necessary during mini-culotte stenting (MCS) and how it can be properly conducted.Methods: MCS was emulated in a bifurcation model with a branch diameter difference (BDD) in three-step sizes of 0.50, 0.75 and 1.00 mm, and with intermediate balloon dilation (IBD) in three treatments of routine intermediate solo balloon dilation (rISBD), concurrent IKBD (cIKBD) or sequential IKBD. Microcomputed tomography was performed to assess stent under-expansion (SUE) around the polygon of confluence (POC), residual ostial stenosis (ROS) at the ostial side-branch (SB) and main-branch (MB) and stent cell distortion (SCD) in the bifurcation segments.Results: There were both main and interactive effects of IBD and BDD on ROS at the ostial SB and SCD in the ostial SB, but there were only main effects of IBD or BDD on SUE around the POC, ROS at the ostial MB and SCD in the ostial MB. Analysis of the main effects showed that SUE around the POC or ROS at the ostial SB was significantly different between sIKBD and rISBD and between cIKBD and rISBD. There was also a significant difference in SCD in the ostial SB between sIKBD and rISBD and between sIKBD and cIKBD. Analysis of the interactive effects showed that ROS at the ostial SB or SCD in the ostial SB was affected by all IBD treatments in all BDD step-sizes. Moreover, increasing the BDD step-sizes significantly increased ROS at the ostial SB as treated by rISBD and SCD in the ostial SB as treated by rISBD or cIKBD.Conclusions: SIKBD was shown to be essential and superior to rISBD or cIKBD, resulting in better bifurcated stent expansion and coverage when using MCS. Keywords: coronary bifurcation, culotte stenting, intermediate kissing dilation
| Reference Key |
cai2018journalnecessity
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Wei Cai;Lianglong Chen;Linlin Zhang;Zhixiong Wei;Sheng Tu;Lin Fan |
| Journal | science education |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.