Determining biological variation of serum parathyroid hormone in healthy adults.
Clicks: 343
ID: 13562
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
65.8
/100
343 views
258 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #5 of 12 articles by views in biochemia medica
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Measurement of parathyroid hormone (PTH) is essential in the investigation and management of calcium metabolism disorders. To assess the significance of any assay result when clinical decision making biological variation (BV) of the measurand must be taken into consideration. The aim of the present study is determining the BV parameters for serum PTH.Blood samples were taken at weekly intervals from 20 healthy subjects for ten weeks in this prospective BV study. Serum "intact PTH" concentrations were measured with electrochemiluminescence method. Biological variation parameters were estimated using the approach proposed by Fraser.The values of within-subject biological variation (CV), between-subject biological variation (CV), analytical variation (CV), reference change value (RCV) and individuality index (II) for serum PTH were 21.1%, 24.9%, 3.8%, 59.4% and 0.8%, respectively. Within-subject biological variation and CV were also determined according to gender separately; 18.5% and 24.0%; 26.2% and 18.6% for male and female, respectively. Calculated desirable precision and bias goals were < 10.6% and < 6.3%, respectively.This study may contribute to BV data on serum PTH as it includes a sufficient number of volunteers from both genders over an acceptable period of time. We do not recommend the usage of population-based reference intervals for serum PTH concentrations. Reference change value may be helpful for the evaluation of serial serum PTH results. Nonetheless, evaluation of data according to gender is necessary when setting analytical performance specifications.
| Reference Key |
ercan2019determiningbiochemia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ercan, Müjgan;Akbulut, Emiş Deniz;Avcı, Esin;Yücel, Çiğdem;Oğuz, Esra Fırat;Turhan, Turan;Serdar, Muhittin; |
| Journal | biochemia medica |
| Year | 2019 |
| DOI |
10.11613/BM.2019.030702
|
| URL | |