evaluation of the reference numerical parameters of the monthly method in iso 13790 considering s/v ratio
Clicks: 4
ID: 134691
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
0.9
/100
4 views
2 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #925 of 935 articles by views in journal of physics: conference series
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 935 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Many studies have investigated the accuracy of the numerical parameters in the application of the quasi steady-state calculation method. The aim of this study is to derive the reference numerical parameters of the ISO 13790 monthly method by reflecting the surface-to-volume (S/V) ratio and the characteristics of the structures. The calculation process was established, and the parameters necessary to derive the reference numerical parameters were calculated based on the input data prepared for the established calculation processes. The reference numerical parameters were then derived through regression analyses of the calculated parameters and the time constant. The parameters obtained from an apartment building and the parameters of the international standard were both applied to the Passive House Planning Package (PHPP) and EnergyPlus programs, and the results were analyzed in order to evaluate the validity of the results. The analysis revealed that the calculation results based on the parameters derived from this study yielded lower error rates than those based on the default parameters in ISO 13790. However, the differences were shown to be negligible in the case of high heat capacity.
| Reference Key |
kwak2015sustainabilityevaluation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Hee-Jeong Kwak;Jae-Hun Jo;Seung-Jik Suh |
| Journal | journal of physics: conference series |
| Year | 2015 |
| DOI |
10.3390/su7010767
|