standard manual reprocessing of angiographic systems in the hybrid or
Clicks: 57
ID: 133401
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
16.8
/100
57 views
7 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #94 of 96 articles by views in materials science and engineering c
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A current FDA guidance demands the validation of cleaning and disinfecting protocols even for non-sterile medical devices. The aim of this work is to clarify whether this is already possible using the guidance itself as well as the German DIN EN ISO 17664. An angiography system (Artis Zeego / Pheno - Siemens) was selected as a test object for the validation of a cleaning and disinfection protocol for medical devices in a hybrid operating room. In pilot study prior to the trial, critical points of the system were evaluated by means of questionnaires to clinical users (OTA, surgical technicians). An initial assessment of the in-house cleaning protocols used in the hospitals was done by using a fluorescence assay. The microbiological examination took place subsequently by contact plates and swabbing to determine the amount and type of germs on the surfaces of the system. These experiments were done at three different clinical sites. It was found that there was a significant germ count on several surfaces of the product even after in-house cleaning and disinfection (C&D). After application of an enhanced C&D plan, these germs could be greatly reduced at all verified sites. In addition, it could be shown that DIN EN ISO 17664 can in principle be applied to non-sterile medical products.
| Reference Key |
sebastian2017currentstandard
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Buhl Sebastian;Werner Carina;Bulitta Clemens |
| Journal | materials science and engineering c |
| Year | 2017 |
| DOI |
10.1515/cdbme-2017-0085
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.