a predictive model for dry-growth icing on composite insulators under natural conditions

Clicks: 327
ID: 132735
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #18 of 526 articles by views in acs combinatorial science

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Icing can adversely influence electric power system security. Two main issues are caused by icing: the overload of transmission lines, and the reduction in the insulation ability of the insulators. Most previous research has focused on the flashover characteristics of ice-covered insulators, but research on the icing process of the insulator is seriously lacking. Considering the effect of icing shape, the outer airflow field of an insulator was calculated and the local collision efficiencies of water droplets (β1) were investigated according to the Lagrange algorithm. The simulation showed that the values of β1 on the insulator edge and rod are much higher than on the insulator surface, and both were significantly influenced by the wind speed and median volume diameter (MVD) of the water droplets. Based on thermal balance equations, a dynamic dry-growth icing model was established. Using the natural icing conditions of Xuefeng Mountain (China) as an example, validation experiments were conducted on a composite insulator and the climate parameters measured by multi-cylinders were used to model the icing shape and mass. The results indicate that high wind speed and low temperature increase icing rate; the icing was mainly concentrated on the windward side and the greatest horizontal thickness was generally on the insulator edge. The dry-growth model had an average error lower than 25% for icing thickness and an average error lower than 20% for icing mass, which were affected by icing roughness.
Reference Key
han2018energiesa Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Xingbo Han;Xingliang Jiang;Zhongyi Yang;Conglai Bi
Journal acs combinatorial science
Year 2018
DOI
10.3390/en11061339
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.