impact of surgical procedure artefacts on the hemodynamic parameters of an isoflurane-anesthetized swine cardiopulmonary bypass model

Clicks: 576
ID: 132069
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objectives: This study quantifies cardiopulmonary bypass preparation artefacts on mean systemic arterial pressures (mAP), mean pulmonary arterial pressures (mPAP) and their ratio (mAP/mPAP) in order to assess the usefulness of this ratio as a pharmacodynamic marker for pharmacokinetic/pharmacodynamic modeling studies. Materials and Methods: Fifteen anesthetized swine were monitored every minute before initiation of cardiopulmonary bypass. Percent relative changes from pre-artefact values ( and #916;%) were used during anesthesia induction and stabilization ( and #916;% minute-1 reduction rates). In addition, in some animals, amplitude and duration were recorded for the following procedures: sternotomy, pulmonary artery catheter installation, purse-string sutures and cardiac cannulations. Results: Isoflurane 5% anesthesia induction effect on mAP, lasted on average 5.3+/-2.0 minutes at 5.9+/-1.9 and #916;% minute-1. Isoflurane 2% anesthesia stabilization effect on mAP lasted on average 36.0+/-8.0 min at 0.8+/-0.9 and #916;% minute-1. During stabilization, no change in mAP/mPAP was observed (p=0.68). Average amplitudes of artefacts on mAP were 30-50 and #916;%; almost twice those observed for mPAP and mAP/mPAP for the same manipulations (p<0.05). Pulmonary artery catheter installation artefacts lasted longer than those of other procedures (p<0.05). Average artefact duration was 4.5+/-2.5 minutes (n=160). Conclusions: In isoflurane-anesthetized swine, mAP/mPAP ratio remains constant during anesthesia stabilization, unlike mAP and mPAP individually. Moreover, the ratio shows potential as a pharmacodynamic biomarker for pharmacokinetic/pharmacodynamic studies involving CPB. [Arch Clin Exp Surg 2016; 5(1.000): 13-20]
Reference Key
gavra2016archivesimpact Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal archives of clinical and experimental surgery
Year 2016
DOI
10.5455/aces.20150813034247
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.