a vector-controlled distributed generator model for a power flow based on a three-phase current injection method

Clicks: 109
ID: 131409
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #475 of 526 articles by views in acs combinatorial science

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This paper proposes a vector-controlled distributed generator (DG) model for a power flow based on a three-phase current injection method (TCIM). In order to represent the DG models in the power flow, steady-state phase current output equations are formulated. Using these equations, the TCIM power flow formulation is modified to include the DG models. In the proposed power flow, a DG-connected bus is modeled as either a load bus (PQ bus) or a voltage-controlled bus (PV bus), depending on the control mode of the reactive power. However, unlike conventional bus models, the values of the DG-connected bus models are represented by three-phase quantities: three-phase active and reactive power output for a PQ bus, and three-phase active power and positive-sequence voltage for a PV bus. In addition, a method is proposed for representing the reactive power limit of a voltage-control-mode DG by using the q-axis current limit. Utilizing a modified IEEE 13-bus test system, the accuracy of the proposed method is verified by comparison to the power systems computer aided design (PSCAD) model. Furthermore, the effect of the number of DGs on the convergence rate is analyzed, using the IEEE 123-bus test system.
Reference Key
ahn2013energiesa Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Seon-Ju Ahn;Pyeong-Ik Hwang;Seung-Il Moon
Journal acs combinatorial science
Year 2013
DOI
10.3390/en6084269
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.