trajectory planning method for improving alignment accuracy of probes for dual-robot air-coupled ultrasonic testing system

Clicks: 349
ID: 130741
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #3 of 10 articles by views in thai journal of obstetrics and gynaecology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Composite workpieces, especially the complex-curved surfaces composite workpieces, have been increasingly used in different industries. Non-destructive testing of these parts has become an urgent problem to be addressed. To solve the problem, this article presents a dual-robot air-coupled ultrasonic non-destructive testing scheme and introduces the structure of the system and a general calibration method for the workpiece frame of a dual-robot system in detail. Importantly, this article proposes a tangential constraint method, which makes the probes completely aligned during the inspection process. Verification experiments and ultrasonic testing experiments for a glued multilayered composite workpiece were performed using the dual-robot air-coupled ultrasonic non-destructive testing system. A comparative experiment was also performed using a dual-robot water jet-coupling ultrasonic testing system. Experimental results show that the dual-robot non-destructive testing scheme and the tangential constraint method function well, and all the artificial defects on the sample can be detected by both kinds of testing methods. Vivid 3-D C-scan image based on the test result is provided for convenience of observation. In other words, a kind of flexible versatile testing platform with multiple degrees of freedom is established.
Reference Key
guo2019internationaltrajectory Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Canzhi Guo;Chunguang Xu;Dingguo Xiao;Juan Hao;Hanming Zhang
Journal thai journal of obstetrics and gynaecology
Year 2019
DOI
10.1177/1729881419842713
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.