determination of residues of sulfonylurea herbicides in soil by using microwave-assisted extraction and high performance liquid chromatographic method
Clicks: 238
ID: 130212
2017
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
73.3
/100
232 views
188 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
A modified method for the analysis of nicosulfuron, rimsulfuron and prosulfuron was developed and validated by using microwave-assisted extraction (MAE) and ultra-performance liquid chromatography with diode array detection in the ultraviolet region (HPLC-UV-DAD). The most important experimental parameters of extraction procedure and HPLC-UV-DAD technique were optimised in respect to those sulfonylurea herbicides. High recoveries of the microwave-assisted extraction were obtained by using a dichloromethane–acetonitrile mixture (2:1 volume ratio) acidified with acetic acid (0.8 vol.%) with the addition of urea. The mean recoveries at three spiking levels ranged from 97.47 to 98.76% for nicosulfuron, 97.88 to 99.17% for rimsulfuron and from 97.91 to 99.83% for prosulfuron. The limits of detection of nicosulfuron, rimsulfuron and prosulfuron were 0.95, 0.91 and 0.89 μg kg–1, respectively. The accuracy of the developed method was confirmed by HPLC coupled with tandem mass spectrometry parallel analyses. The developed method was used to investigate the dissipation dynamics of sulfonylurea herbicides in the real field trials in Vojvodina Province, Serbia. The obtained half-lives were 0.05, 0.23 and 0.15 days for recommended dose application of nicosulfuron, rimsulfuron and prosulfuron, respectively. Low residues and short half-life in soil suggested that the risk to sensitive rotational crops after application of those sulfonylurea herbicides is low when they are used in the appropriate dosages. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR 31072]
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (212 words).
Try re-searching for a better abstract.
| Reference Key |
l.2017hemijskadetermination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Grahovac Nada L.;Stojanović Zorica S.;Kravić Snežana Ž.;Orčić Dejan Z.;Suturović Zvonimir J.;Kondić-Špika Ankica Đ.;Vasin Jovica R.;Šunjka Dragana B.;Jakšić Snežana P.;Rajković Miloš M.;Grahovac Nenad M. |
| Journal | lecture notes in information systems and organisation |
| Year | 2017 |
| DOI |
10.2298/HEMIND160224039G
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.