plateletpheresis adverse events in relation to donor and plateletpheresis session profile

Clicks: 164
ID: 129697
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction: Increasing demand of platelet transfusions for patients has led to a trend in the increased use of automated blood collections. These share many of the same reactions and injuries seen with pooled platelets obtained from whole blood donation but also have unique complications. Aims And Objectives: To study the adverse events (AEs) of plateletpheresis procedure and their relationship with donor and plateletpheresis procedure session profiles. Materials And Methods: This is a retrospective observational study conducted from January 2016 to December 2016. A two-hundred and thirteen (213) plateletpheresis procedures were performed after taking informed and written consent from the donor. All the donors were male and selected according to the guidelines laid down by Director General of Health Services. The AEs were classified into donor related, kit/equipment related and technique related. Results: A total of 13 AEs were noted; of which, 8 (61.53 %) events were associated with donors, 3 (23.07 %) were owed to fault in kit/equipment and 2 (15.384 %) were due to technical aberrations. Donor related AEs included vascular injuries [n = 3 (1.40%)], vasovagal reactions [n = 2 (0.938%)] and perioral tingling sensation [n = 3 (1.40%)]. Technique related AEs [n = 2 (0.938%)] and kit/equipment related AEs [n = 3 (1.40%)] were due to faulty technique and defective kits respectively. Conclusion: Apheresis donations performed on cell separators are safe. Meticulous donor vigilance, superior technical personnel training and experienced transfusion medicine specialist's supervision will make donor's experience more pleasant.
Reference Key
bassi2017iraqiplateletpheresis Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal iraqi journal of hematology
Year 2017
DOI
10.4103/ijh.ijh_14_17
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.