evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in ni-cr-ti and pd-ag alloys

Clicks: 268
ID: 129471
2003
Free PDF
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #5 of 7 articles by views in qualitative research

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supported prostheses obtained in Ni-Cr-Ti alloy, compared to a semi-noble alloy Pd-Ag. Eight superstructures for each alloy were produced over 4 implants in the anterior region of the mandible. The superstructures were placed in a torquemeter and the fixation screw of implant #1 was tightened with a 20 Ncm load with the others loosened (Sheffield test). The unfitness (in mm) was measured using a three-dimensional optical measurer in each implant, in the buccal and lingual aspects. The obtained data were submitted to statistical analysis by the analysis of variance and Tukey's test at 5% level. Significant differences were found for the factors material (p<0.05), with Ni-Cr-Ti pieces better than Pd-Ag ones, and implants (p<0.01). There were no significant differences for the factor position and interactions among factors (p>0.05). Based on the analysis of the data, it is possible to conclude that the Ni-Cr-Ti alloy makes possible the obtainment of one-piece implant-supported superstructures with a smaller misfit compared to the one obtained in Pd-Ag alloy, traditionally indicated for this situation. Additional tests may verify the superiority of the Ni-Cr-Ti alloy.
Reference Key
da2003brazilianevaluation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal qualitative research
Year 2003
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.